Eternalight I
|
|
Emergency Lighting Inverter (Single Phase, 3 - 18 kVA)
|
|
|
|
 |
 |
 |
UL 924 |
 |
High Efficiency >92% |
 |
Reliability (200,000 hrs.) |
 |
Energy Star Rated - TP1 |
 |
Industrial Application |
 |
Service Access Front Only |
 |
DSP/PWM Inverter |
 |
Proven Non-linear load Capability |
 |
90 Minutes Battery Backup |
 |
Incandescent, Fluorescent, HID, and HPcompatible
|
|
|

 |
Maintenance Bypass Switch |
 |
Outdoor or Harsh Enviroment Enclosure |
 |
Phoenix "Hydrogen Off- Gasing Termination" |
 |
Output Circuit Breakers |
 |
Normally - Off Output Circuit Breakers |
 |
Seismic Rated Bracket
|
 |
Normally - Off Output
|
 |
Remote Shutdown
|
 |
Remote Panel
|
 |
Normally - Off "Hold-On" |
*Specifications are subject to change without notice.

|
|
|
BATTERIES
- Sealed, maintenance-free, lead acid (AGM) batteries.
- 10 year prorated warranty
- DSP Smart Battery Monitoring System is temperature compensated maintaining maximum runtime and battery life
- Microprocessor controlled recharge and DSP overcharge protection standard |
|
LAMPS AND LOADS
- Emergency power provides FULL LIGHT OUTPUT from all lamps and fixtures for the entire runtime
- Compatible with fluorescent, compact fluorescent, incandescent, quartz, H.I.D., LED and other lamp types
- Standard or LED Exits and other safety equipment |
|
PROTECTION
- Provides overload, surge and undercurrent protection using DSP/PWM "Watchdog Monitoring" Protection System
- Surge protection against load surges as defined in ANSI/IEEE C62.45 category A and B |
|
DIAGNOSTICS AND MAINTENANCE
- DSP/PWM Watchdog Monitoring System provides complete self-diagnostic capabilities
- Informative advanced DSP Metering Display and Alarms keep you in control of your emergency lighting environment 24/7
- Automatically performs periodic self-tests ensuring a safety lighted environment prior to an emergency
- Single point of testing instead of hundreds with battery packs. |
|
CABINET
- Free Standing Indoor or Outdoor available
- NEMA 1 standard
NEMA 3R 4X or NEMA 12X for harsh environments
- Modular design enables flexible installation
- Forced air cooling for maximum reliability
- Systems up to 7.5 KVA are self contained; larger systems require external Battery Cabinet(s) |
|
INSTALLATION
- Modular design and small footprint allow easy installation in electrical closet or other convenient locations
- Factory Start-Up available on all systems |
|
SPECIAL APPLICATIONS
- DSPM PowerClone offers numerous UL924 optional devices to meet unusual or difficult application parameters
- ECI - Patented Emergency Circuit Interface modules allow fixtures and lamps on the emergency circuit(s) to be operated by normal switching and/or dimming devices in NON-emergency conditions
- Phoenix "HOT" Switch (Hydrogen Off-gassing Termination)
- Dimming Panel Interface allows use with emergency lights controlled by common dimmer panel
- DSP Remote Shutdown and programmable timers help stabilize lighting environment |
|
CODES
- CSA Listed to UL924, NFPA 101, NFPA 70, NEC and OSHA |
|
WARRANTY
- 1-year full warranty on system electronics. Battery warranty 1-year with 9-years pro-rata. System 1-year on-site warranty labor with DSPM supervised Start-Up.
- Maintenance contracts available. |
|

|
:: Emergency (egress) Central Lighting Inverter
|
|
The "Eternalight" - uses DSP/PWM inverter technology. This guarantees that no matter what lamp you're using, from HID, HPS, Incandescent, or Fluorescent this is the system for your application. The product line is Listed to UL924
|
|
:: Industrial "Giant" |
|
The "Eternalight" optional NEMA enclosures makes it an ideal candidate for the harsh environment conditions that exist in industrial applications. The unit can be housed in a NEMA 3R or a totally enclosed 4X or 12X cabinet.
|
|
:: Outdoor or Remote Site |
|
The "Eternalight" has the enclosure and the monitoring package that will allow the end user to select the site, indoor or outdoor, control and self diagnostic capabilities. The location is no longer a controlling factor.
|
|
:: Phoenix "HOT" Switch |
|
The DSPM Eternalight, Emergency Lighting UPS, features the Phoenix Hydrogen Off-gassing Termination (HOT) Switch. When the facilityexhaust fan stops, the battery charger will stop charging, but the inverter will continue to operate and will continue to provide power to the load with full battery back up.
|
|
|
 |
Full-light output |
from lamps & fixtures |
 |
Self-diagnostics |
keeps lighting environment safe & secure |
 |
DSPM/Watchdog |
software automatic programmable testing |
 |
LCD Display Monitor |
keeps you in control 24/7 |
 |
Pure sine wave |
output powers all types of lamps |
 |
Modular |
small footprint uses space wisely |
 |
Powerful |
4.7-25.5 KVA full-load capabilities |
 |
Dependable |
DSP/PWM technology for unsurpassed reliability |
 |
Economical |
lowest overall costs for life safety |
 |
Made is USA |
|
 |
ECI Modules |
use DSPM patented technology |
 |
Versatile |
back-up solution for multiple applications: indoor & outdoor emergency lighting, exits, cash registers, computers, strategic electronics and more |
 |
Installation contractor friendly |
with easy access |
 |
Long Battery life temperature compensating |
technology monitors batteries |
 |
Meets federal, state and local codes |
UL924, NFPA 101, NFPA 70, NEC and OSHA |
|
|

|
 |
|


| *Power Rating |
3, 5, 7.5, 10, 12.5, 15, or 18 kVA
|
| *Input Voltage |
*120, 208, 240, or 277 VAC |
| *Input Voltage Reg. Range |
+10%, -15% |
| *Output Voltage |
120, 208, 240, 277, 120/240 VAC |
| *Output Voltage Regulation |
±2% typical |
| *Output Frequency Range |
60 Hz ±5% |
| *Output Wave Form |
Sine-wave <5% @ 100% linear load |
| *Crest Factor |
2.5:1 Typical |
| *Input Protection |
Input Main Circuit Breaker |
| *Output Protection |
Output Main Circuit Breaker |
| *Surge Protection |
The unit will protect itself and the load against surges as defined in ANSI/IEEE C62.45 category A and B. |
| *Output Transformer |
Shield, isolation transformer |
| *Isolation |
Complete from line |
| *Battery |
Sealed maintenance-free (AGM) lead acid |
| *Recharge Current |
Conforms to UL 924 Standard |
| *External battery |
Provision for hardwire connection of external battery cabinets or DC source. |
| *Efficiency |
>92% at 100% linear load |
| *Audible Noise |
<58 dB measured on Response Curve "A" |
| *Safety Agencies |
Listed to UL 924 Standard |
| *Operating Temperature |
0 to 40C (32 to 104F.) |
| *Storage Temperature |
-20 to 60C (-4 to 140F.) |
| *Humidity |
5 - 95% Non-condensing |
* Consult factory for others, Specifications are subject to change without notice.
|
|
SIZES
(KVA) |
INPUT / OUTPUT
VOLTAGE
|
MODEL NUMBERS
|
WATTS
|
CABINET
W x H x D
|
COMBINED
WEIGHTS
|
|
3
(KVA)
|
120 VAC / 120 VAC |
CC3.0160206-090 |
2,100W |
INV /
42"W x 22.5"D x 48"H
BATT / CAB NOT
REQUIRED
|
725 LBS
|
| 208 VAC / 208 VAC |
CC3.0160410-090 |
| 240 VAC / 240 VAC |
CC3.0160822-090 |
| 277 VAC / 277 VAC |
CC3.0160923-090 |
120,208,240,277 VAC
120,208,240,277 VAC |
CC3.0161912-090 |
|
5
(KVA)
|
120 VAC / 120 VAC |
CC5.0160206-090 |
3,500W |
INV /
42"W x 22.5"D x 48"H
BATT / CAB NOT
REQUIRED
|
1,650 LBS
|
| 208 VAC / 208 VAC |
CC5.0160410-090 |
| 240 VAC / 240 VAC |
CC5.0160822-090 |
| 277 VAC / 277 VAC |
CC5.0160923-090 |
120,208,240,277 VAC
120,208,240,277 VAC |
CC5.0160912-090 |
|
7.5
(KVA)
|
208 VAC / 208 VAC |
CC7.5160410-090 |
5,250W |
INV /
42"W x 22.5"D x 71"H
BATT / CAB NOT
REQUIRED
|
1,700 LBS
|
| 240 VAC / 240 VAC |
CC7.5160822-090 |
| 277 VAC / 277 VAC |
CC7.5160923-090 |
120,208,240,277 VAC
120,208,240,277 VAC |
CC7.5161912-090 |
|
10
(KVA)
|
208 VAC / 208 VAC |
CC010160410-090 |
7,000W |
INV /
42"W x 22.5"D x 48"H
BATT /42"W x 22.5"D x 71"H
|
2,200 LBS
|
| 240 VAC / 240 VAC |
CC010160822-090 |
| 277 VAC / 277 VAC |
CC010160923-090 |
208,240,277 VAC
120,240,277 VAC |
CC010160912-090 |
|
12.5
(KVA)
|
208 VAC / 208 VAC |
CC012160912-090 |
8,750W |
INV /
42"W x 22.5"D x 48"H
BATT /42"W x 22.5"D x 71"H
|
2,550 LBS
|
| 240 VAC / 240 VAC |
CC012160822-090 |
| 277 VAC / 277 VAC |
CC012160923-090 |
208,240,277 VAC
120,240,277 VAC |
CC012160912-090 |
|
15
(KVA)
|
208 VAC / 208 VAC |
CC015160912-090 |
10,500W |
INV /
42"W x 22.5"D x 48"H
BATT /42"W x 22.5"D x 71"H
|
3,150 LBS
|
| 240 VAC / 240 VAC |
CC015160912-090 |
| 277 VAC / 277 VAC |
CC015160912-090 |
208,240,277 VAC
120,240,277 VAC |
CC015160912-090 |
|
18
(KVA)
|
208 VAC / 208 VAC |
CC018160912-090 |
12,600W |
INV /
42"W x 22.5"D x 48"H
BATT /42"W x 22.5"D x 71"H
|
3,800 LBS
|
| 240 VAC / 240 VAC |
CC018160912-090 |
| 277 VAC / 277 VAC |
CC018160912-090 |
208,240,277 VAC
120,240,277 VAC |
CC018160912-090 |
|

|
|
|
|