Home >> Products >> Lighting Inverter >> 1 Phase In / Out >> Eternalight 1
Eternalight I
Emergency Lighting Inverter (Single Phase, 3 - 18 kVA)

UL 924

High Efficiency >92%

Reliability (200,000 hrs.)

Energy Star Rated - TP1

Industrial Application

Service Access Front Only

DSP/PWM Inverter

Proven Non-linear load Capability

90 Minutes Battery Backup

Incandescent, Fluorescent, HID, and HPcompatible





Maintenance Bypass Switch
Outdoor or Harsh Enviroment Enclosure
Phoenix "Hydrogen Off- Gasing Termination"
Output Circuit Breakers
Normally - Off Output Circuit Breakers
Seismic Rated Bracket
Normally - Off Output
Remote Shutdown
Remote Panel
Normally - Off "Hold-On"

*Specifications are subject to change without notice.


BATTERIES

- Sealed, maintenance-free, lead acid (AGM) batteries.

- 10 year prorated warranty

- DSP Smart Battery Monitoring System is temperature compensated maintaining maximum runtime and battery life

- Microprocessor controlled recharge and DSP overcharge protection standard

LAMPS AND LOADS

- Emergency power provides FULL LIGHT OUTPUT from all lamps and fixtures for the entire runtime

- Compatible with fluorescent, compact fluorescent, incandescent, quartz, H.I.D., LED and other lamp types

- Standard or LED Exits and other safety equipment

PROTECTION

- Provides overload, surge and undercurrent protection using DSP/PWM "Watchdog Monitoring" Protection System

- Surge protection against load surges as defined in ANSI/IEEE C62.45 category A and B

DIAGNOSTICS AND MAINTENANCE

- DSP/PWM Watchdog Monitoring System provides complete self-diagnostic capabilities

- Informative advanced DSP Metering Display and Alarms keep you in control of your emergency lighting environment 24/7

- Automatically performs periodic self-tests ensuring a safety lighted environment prior to an emergency

- Single point of testing instead of hundreds with battery packs.

CABINET

- Free Standing Indoor or Outdoor available

- NEMA 1 standard

NEMA 3R 4X or NEMA 12X for harsh environments

- Modular design enables flexible installation

- Forced air cooling for maximum reliability

- Systems up to 7.5 KVA are self contained; larger systems require external Battery Cabinet(s)

INSTALLATION

- Modular design and small footprint allow easy installation in electrical closet or other convenient locations

- Factory Start-Up available on all systems

SPECIAL APPLICATIONS

- DSPM PowerClone offers numerous UL924 optional devices to meet unusual or difficult application parameters

- ECI - Patented Emergency Circuit Interface modules allow fixtures and lamps on the emergency circuit(s) to be operated by normal switching and/or dimming devices in NON-emergency conditions

- Phoenix "HOT" Switch (Hydrogen Off-gassing Termination)

- Dimming Panel Interface allows use with emergency lights controlled by common dimmer panel

- DSP Remote Shutdown and programmable timers help stabilize lighting environment

CODES

- CSA Listed to UL924, NFPA 101, NFPA 70, NEC and OSHA

WARRANTY

- 1-year full warranty on system electronics.  Battery warranty 1-year with 9-years pro-rata.  System 1-year on-site warranty labor with DSPM supervised Start-Up.

- Maintenance contracts available.




:: Emergency (egress) Central Lighting Inverter

The "Eternalight" - uses DSP/PWM inverter technology. This guarantees that no matter what lamp you're using, from HID, HPS, Incandescent, or Fluorescent this is the system for your application. The product line is Listed to UL924

:: Industrial "Giant"

The "Eternalight" optional NEMA enclosures makes it an ideal candidate for the harsh environment conditions that exist in industrial applications. The unit can be housed in a NEMA 3R or a totally enclosed 4X or 12X cabinet.

:: Outdoor or Remote Site

The "Eternalight" has the enclosure and the monitoring package that will allow the end user to select the site, indoor or outdoor, control and self diagnostic capabilities. The location is no longer a controlling factor.

:: Phoenix "HOT" Switch

The DSPM Eternalight, Emergency Lighting UPS, features the Phoenix Hydrogen Off-gassing Termination (HOT) Switch. When the facilityexhaust fan stops, the battery charger will stop charging, but the inverter will continue to operate and will continue to provide power to the load with full battery back up.


Full-light output

from lamps & fixtures

Self-diagnostics

keeps lighting environment safe & secure

DSPM/Watchdog

software automatic programmable testing

LCD Display Monitor

keeps you in control 24/7

Pure sine wave

output powers all types of lamps

Modular

small footprint uses space wisely

Powerful

4.7-25.5 KVA full-load capabilities

Dependable

DSP/PWM technology for unsurpassed reliability

Economical

lowest overall costs for life safety

Made is USA

ECI Modules

use DSPM patented technology

Versatile

back-up solution for multiple applications:  indoor & outdoor emergency lighting, exits, cash registers, computers, strategic electronics and more

Installation contractor friendly

with easy access

Long Battery life temperature compensating

technology monitors batteries

Meets federal, state and local codes

UL924, NFPA 101, NFPA 70, NEC and OSHA









*Power Rating 3, 5, 7.5, 10, 12.5, 15, or 18 kVA
*Input Voltage *120, 208, 240, or 277 VAC
*Input Voltage Reg. Range +10%, -15%
*Output Voltage 120, 208, 240, 277, 120/240 VAC
*Output Voltage Regulation ±2% typical
*Output Frequency Range 60 Hz ±5%
*Output Wave Form Sine-wave <5% @ 100% linear load
*Crest Factor 2.5:1 Typical
*Input Protection Input Main Circuit Breaker
*Output Protection Output Main Circuit Breaker
*Surge Protection The unit will protect itself and the load against surges as defined in ANSI/IEEE C62.45 category A and B.
*Output Transformer Shield, isolation transformer
*Isolation Complete from line
*Battery Sealed maintenance-free (AGM) lead acid
*Recharge Current Conforms to UL 924 Standard
*External battery Provision for hardwire connection of external battery cabinets or DC source.
*Efficiency >92% at 100% linear load
*Audible Noise <58 dB measured on Response Curve "A"
*Safety Agencies Listed to UL 924 Standard
*Operating Temperature 0 to 40C (32 to 104F.)
*Storage Temperature -20 to 60C (-4 to 140F.)
*Humidity 5 - 95% Non-condensing 

* Consult factory for others,  Specifications are subject to change without notice.



SIZES
(KVA)
INPUT / OUTPUT
VOLTAGE
MODEL NUMBERS
WATTS
CABINET
W x H x D
COMBINED
WEIGHTS
3

(KVA)

120 VAC / 120 VAC CC3.0160206-090 2,100W
INV /
42"W x 22.5"D x 48"H
BATT / CAB NOT
REQUIRED
725 LBS
208 VAC / 208 VAC CC3.0160410-090
240 VAC / 240 VAC CC3.0160822-090
277 VAC / 277 VAC CC3.0160923-090
120,208,240,277 VAC
120,208,240,277 VAC
CC3.0161912-090
5

(KVA)

120 VAC / 120 VAC CC5.0160206-090 3,500W
INV /
42"W x 22.5"D x 48"H
BATT / CAB NOT
REQUIRED
1,650 LBS
208 VAC / 208 VAC CC5.0160410-090
240 VAC / 240 VAC CC5.0160822-090
277 VAC / 277 VAC CC5.0160923-090
120,208,240,277 VAC
120,208,240,277 VAC
CC5.0160912-090
7.5

(KVA)

208 VAC / 208 VAC CC7.5160410-090 5,250W
INV /
42"W x 22.5"D x 71"H
BATT / CAB NOT
REQUIRED
1,700 LBS
240 VAC / 240 VAC CC7.5160822-090
277 VAC / 277 VAC CC7.5160923-090
120,208,240,277 VAC
120,208,240,277 VAC
CC7.5161912-090
10

(KVA)

208 VAC / 208 VAC CC010160410-090 7,000W
INV /
42"W x 22.5"D x 48"H
BATT /42"W x 22.5"D x 71"H
2,200 LBS
240 VAC / 240 VAC CC010160822-090
277 VAC / 277 VAC CC010160923-090
208,240,277 VAC
120,240,277 VAC
CC010160912-090
12.5

(KVA)

208 VAC / 208 VAC CC012160912-090 8,750W
INV /
42"W x 22.5"D x 48"H
BATT /42"W x 22.5"D x 71"H
2,550 LBS
240 VAC / 240 VAC CC012160822-090
277 VAC / 277 VAC CC012160923-090
208,240,277 VAC
120,240,277 VAC
CC012160912-090
15

(KVA)

208 VAC / 208 VAC CC015160912-090 10,500W
INV /
42"W x 22.5"D x 48"H
BATT /42"W x 22.5"D x 71"H
3,150 LBS
240 VAC / 240 VAC CC015160912-090
277 VAC / 277 VAC CC015160912-090
208,240,277 VAC
120,240,277 VAC
CC015160912-090
18

(KVA)

208 VAC / 208 VAC CC018160912-090 12,600W
INV /
42"W x 22.5"D x 48"H
BATT /42"W x 22.5"D x 71"H
3,800 LBS
240 VAC / 240 VAC CC018160912-090
277 VAC / 277 VAC CC018160912-090
208,240,277 VAC
120,240,277 VAC
CC018160912-090