Power Lynx Plus
PLC Series Emergency Lighting System(2.4KW - 4.2 KW)

The Power Lynx is always on-line, eliminating noise, spikes, surges and brownouts. When the utility fails, the Power Lynx inverter will continue to provide AC voltage without the slightest interruption.

The Power Lynx's inverter generates an output sine wave that uses a high frequency PWM. The output voltages available are 208Y/120 or 480Y/277 (consult the factory for others). The output Transformer isolates your critical load from the any source of noise. The inverter uses an output transformer in the Power Lynx that will always protect your equipment.

Our monitoring is very comprehensive. Each output voltage is monitored for voltage, current and KVA levels. Even if the output voltages are 120 and 277, each output is monitored independently so you always know what is going on with your critical loads. The input is monitored adjustable via the
front panel. The microprocessor will store any alarm so a history is always available. The RS 232 and RS 485 ports will allow for remote monitoring.

The Power Lynx's battery charger is temperature compensated for maximum battery life. We use sealed maintenance free batteries (other batteries are available, please check with the factory), the microprocessor is settable to exercise the batteries on a regulator bases, and so the battery is never a question. An automatic battery equalize is also provided. The equalize operation is settable, so the battery can be equalized according to the battery manufacturer guidelines for your application.



UL 1778

High Efficiency >92%

Reliability (200,000 hrs.)

Energy Star Rated - TP1

Industrial Application

Service Access Front Only

DSP/PWM Inverter

Proven Non-linear load Capability





Maintenance Bypass Switch
Outdoor or Harsh Enviroment Enclosure
Phoenix "Hydrogen Off- Gasing Termination"
Output Circuit Breakers
Normally - Off Output Circuit Breakers
Seismic Rated Bracket
Remote Panel

*Specifications are subject to change without notice.










*Power Rating 2.4, 2.8, 3.2, 3.8 and 4.2 KW
*Input Voltage 120, 208, 240, or 277VAC
*Input Voltage Reg. Range +10%, -15%
*Output Voltage 120 or 277 VAC
*Output Voltage Regulation ±2% typical
*Output Frequency Range 60 Hz ±5%
*Output Wave Form Sine-wave <5% @ 100% linear load
*Crest Factor 2.5:1 Typical
*Input Protection Input Main Circuit Breaker
*Output Protection Output Main Circuit Breaker
*Surge Protection The unit will protect itself and the load against surges as defined in ANSI/IEEE C62.45 category A and B.
*Output Transformer Shield, isolation transformer
*Isolation Inverter complete from line
*Battery Sealed maintenance-free (AGM) lead acid
*Recharge Current 10 times discharge
*External battery Provision for hardwire connection of external battery cabinets or DC source.
*Efficiency >92%
*Audible Noise <45 dB measured on Response Curve "A"
*Safety Agencies UL 1778
*Operating Temperature 0 to 40C (32 to 104F.)
*Storage Temperature -20 to 60C (-4 to 140F.)
*Humidity 5 - 95% Non-condensing 

* Consult factory for others,  Specifications are subject to change without notice.


Power
Lynx
Plus
Power
Rating
UPS
Weight
OCB
Battery
Type
Voltage
(VAC)
Audible Noise
Safety Approvals
Dimentions Sealed
Mainte
nance
Free
(AGM)
Lead
Acid
Input Output <44dB measured on Response Curve "A" CSA to UL 924 NFPA 101 NFPA 70 NEC
Power
lynx
Plus
VA/KW W H
D
(LBS)
Available in increments of1,3,6,9 or 12
Select

120
208
240
or
277
Select

120/
240
or
277
3.4/2.4 26"
44"
26"
743
3.7/2.6 26"
44"
26"
743
4/2.8 26"
44"
26"
1022
4.3/3 26"
44"
26"
1022
4.6/3.2 26"
44"
26"
1022
4.9/3.4 26"
44"
26"
1022
5.1/3.6 26"
44"
26"
1304
5.4/3.8 26"
44"
26"
1304
5.7/4 26"
44"
26"
1304
6/4.2 24" 25"
26"
1304